If you’re not sure which Thermochron is right for you, call us on 1300 30 33 34 for great advice.
In order to configure your Thermochrons and read their data, you will need a Reader.
Our Readers come complete with USB attachment.
…and the best Thermochron Software.
Included with our Readers is a full licence of eTemperature – the easiest, most powerful software written for Thermochrons.
eTemperature makes configuring your Thermochrons easy, with one-click set-up for most common uses.
Basic – TC | Super – TCS | Extreme – TCX | Humidity – HC | |
---|---|---|---|---|
Part No. | DS1921G | DS1922L | DS1922T | DS1923 |
Memory size | 2,048 Readings e.g. Approx. 7 days at 5 minute sample interval |
8,192 Readings (8 bit) 4,096 Readings (11 bit) e.g. Between approx. 14 and 28 days at 5 minute sample interval |
8,192 Readings (8 bit) 4,096 Readings (11 bit) e.g. Between approx. 14 and 28 days at 5 minute sample interval |
4,096 Readings (8 bit) 2,048 Readings (11 bit) per channel |
Range (°C) | -40°C to 85°C | -40°C to 85°C | 0°C to 125°C | -20°C to 85°C 0 to 100% Relative Humidity |
Resolution (°C) | 0.5°C | Programmable 0.5°C – 8 bit or 0.0625°C – 11 bit |
Programmable 0.5°C – 8 bit or 0.0625°C – 11 bit |
Programmable 0.5°C – 8 bit or 0.0625°C – 11 bit |
Temperature Accuracy | ± 1°C: -30°C to +70°C ± 1.3°C outside this range |
± 0.5°C: -10°C to +65°C | ± 0.5°C: +20°C to +75°C | Better Than ±0.5°C from-10°C to +65°C with Software Correction |
Sample interval | 1 minute to 255 minutes | 1 second to 273 hours | 1 second to 273 hours |
1 second to 273 hours |
Battery life | ~5-7 years depending on sample rate | ~5-7 years depending on sample rate | ~5-7 years depending on sample rate | ~5-7 years depending on sample rate |
Humidity resolution | Programmable 0.6% RH – 8 bit / 0.04% RH – 12 bit |
|||
Humidity accuracy | ± 0.5°C: -10°C to +65°C (With software correction) |
|||
Calibration | Individually Calibrated in a NIST-Traceable Chamber | Individually Calibrated in a NIST-Traceable Chamber | Individually Calibrated in a NIST-Traceable Chamber | Individually Calibrated in a NIST-Traceable Chamber |
Water Resistance | Water Resistant Enclosure (IP56) or Waterproof if Placed Inside DS9107 iButton Capsule | Water Resistant Enclosure (IP56) or Waterproof if Placed Inside DS9107 iButton Capsule | Water Resistant Enclosure (IP56) or Waterproof if Placed Inside DS9107 iButton Capsule | Water Resistant Enclosure (IP56) |
Not sure which Thermochron is right for you? Need a hand setting things up? Got some strange data you want explained?